Toshiba Top Page
 
 
Home > Products  > Building System > SMMS

SMMS

image
 

World-class energy efficiency : COP of 4.25*

COP of 4.25* achieved by Toshiba's unrivalled SMMS technologies and newly developed components.

*When heating with 8HP CDU system

To Top

Greater installation flexibility

An outstanding variety of indoor units - 14 types

An outstanding variety of indoor units - 14 types


Flexible branching

The versatility of the Super MMS means that virtually any imaginable configuration of the refrigerant y-type branches and/or header piping can be used in an application to give the shortest, most cost-effective piping installation. The piping can be run in any direction to facilitate refurbishment work.

Flexible branching

To Top

Improved operation control

The Super MMS control system can achieve flexible centralised network control according to the various customer requirements, for both open-network building control in combination with other building apparatus like elevators, fire alarms, lighting, etc., and also for stand-alone air conditioning central control.

Compliant manager

Touch screen controller

Compliant manager Touch Screen controller

♦Model name
BMS-CM1280TLE
BMS-CM1280FTLE *1

♦Operation
Individual operation 128 indoor units can be operated Return Back Operation Weekly Schedule Operation* (On/OFF)
* accessory necessary

♦Monitoring
Zone setting (64 zone x 2)
Individual units operation mode operation restriction
Alarm display
Control input Status output

*1 Web application

Network connection
Setting Schedule(ON/OFF, Setting temperature, operation mode and Remote control Permit/Prohibit)
Error history electrical power distribution* external connection*
* accessory necessary

♦Model name
BMS-TP0641ACE
BMS-TP5121ACE
BMS-TP0641PWE*
BMS-TP5121PWE*
* With energy monitoring and billing

♦Touch screen controller
Using the touch screen controller with the intelligent server provides a clear display and enables easy operation. Maximum 512 units are controllable by one touch controller.

♦Energy monitoring and billing application
ower meter interface, power meter locally supplied Energy Monitoring relay I/F
(BMS-IFWH4E2)

♦Power meter (Local Supply)
1kWh/pulse or 10kWh/ pulse (Pulse buration 50 to 1000ms) (Maximum 8 power meter per interface)

1. LonWorks®: Resisteved trademark Echelon corporation
2. BACnet®: ANSI/ASHRAE 135-1995, A data Communication Protocol for Building Automation and Control Networks.

Intelligent Server

LN Interface

Intelligent Server LN Interface

♦Model name
BMS-LSV6E
(Server Software: BMS-STBN08E)

♦BACnet®
The BACnet system operates in conjunction with the BAC net server Server and uses object signals providing the following functions.

♦Model name
TCB-IFLN640TLE

♦LonWorks® LN Interface
The LonWorksR interface manages the Super MMS air conditioning system as a Lon device to communicate with the custormer’s Building Management System and to monitor operational status. Maximum 64 units are controllable per interface.

SMMS catalogue
PDF:11.8MB

Get Acrobat Reader


To Top

   
Site Map | Contact Us |  Privacy Policy Copyright